One address for technical questions on any amplifier we have shipped – whether it left the factory last month or has been running in a KTV room for six years. Fault-finding notes, spare parts, repair quotations and commissioning help, in that order.
Most support threads take three or four messages because the first one is missing one of these. Send all three and you usually get an answer, not a question.
Model and serial number from the rear-panel label, plus the revision letter if one is printed. The serial tells us which production batch, board revision and mains variant you have.
What the unit does beats what you think failed. “Channel 2 drops out after 20 minutes at 4 Ω” is diagnosable. “It is broken” is not.
A photo of the rear panel wiring, a short phone video with the LED state visible, and the load connected per channel. If you have a meter reading, include it.
These six account for the large majority of field reports. None of them require opening the unit.
| Symptom | Check first |
|---|---|
| No output on one channel | Swap the input cable between channels. Confirm the channel is not bridged into an unbalanced load, and check the input sensitivity switch – 0.775 V / 1 V / 32 dB on DAI and D series. |
| PROTECT LED stays on | Disconnect the load and re-power. If the LED clears, the fault is downstream: a shorted speaker line, a load below 2 Ω, or DC on the line. |
| Channel cuts out at high level | Over-current or thermal. Check the load per channel, the space between amplifiers and the front filter. A 2 Ω load on a long duty cycle needs far more airflow than 8 Ω. |
| Hum or buzz | Ground loop, almost always. Lift the signal ground at one end only – never the mains earth – and check that XLR pin 1 is not tied to the chassis at both ends of the cable. |
| Fan never slows down | Ambient temperature inside the rack, a blocked front filter, or a rack with no rear exhaust path. Fans track temperature, so a hot rack keeps them at full speed. |
| No power at all | Mains voltage and breaker first, then match the voltage variant on the rear label to the site supply. A 220-240 V unit on a 110 V feed will not start. |
Before you open anything: the amplifiers carry stored energy in the supply capacitors after mains is removed. Work inside a unit only if you are qualified to do so, and never with the load connected.
Coverage follows the terms written on the order confirmation, proforma invoice or quotation you accepted – so the first thing we ask for is your order or invoice number, not a date. Send it with the serial number and we will confirm what applies to that specific unit.
For anything outside that cover we quote before work starts: parts, labour and freight, itemised. Spare boards, fans, knobs, handles and rear-panel connectors are supplied per model rather than as a generic kit, which is why the serial number matters – the same model name can span more than one board revision.
Do not ship a unit back without a return reference. A parcel that arrives without one cannot be matched to a repair, and it will sit in the warehouse while we try to work out whose it is.
If you are about to power a room, send the channel plan and a photo of the finished rack first. We will go through channel assignment, bridging, gain structure and the load per channel with you before anything is switched on – it is a ten-minute check that prevents most of the calls described above.
Full technical data for each range lives on its own page. The 2024 catalogue as a PDF, wiring diagrams and board-level schematics are sent on request – tell us the model and we will send the matching set.
Mils Audio Equipment Co., Guangzhou, China (GMT+8). Technical questions, spare-part enquiries and repair quotations all reach the same team that builds the amplifiers.
WhatsApp +86 176 8880 0314milsaudio@gmail.comAll contact details